CORROSION SERVICE & CATHODIC PROTECTION

We offer flowline inspection and monitoring services using Close Internal Potential Survey (CIPS) and Direct Current Voltage Gradient (DCVG) methods specifically designed for underground pipelines in the oil and gas industry.

  • CIPS: This method measures voltage potential along the pipeline to assess the effectiveness of the cathodic protection system against corrosion. Through these measurements, we can detect areas at risk of corrosion.

  • DCVG: Complementing CIPS, this method detects damage to the pipeline's protective coating, allowing specific corrosion-prone areas to be identified.